4017 decade counter Reset and Enable - Electronic Circuits for the Evil Genius
 
Evil Genius Chip Logo
forum
Electronic Circuits for the Evil Genius
McGraw Hill's Surfing Robo Logo
Home | About EC for the EGLinks
 Contact Mr Cutcher | Site Map
Part III Exercise Key
Lesson 38
Be sure the correct resistor values are in place for this exercise.  

RESET
Just to be sure that it is working at all, touch the Reset Probe from pin 15 to Voltage.  That should bring bring the count back to Output 0 and pin 3 will go high while all other outputs go low.

ENABLE 
Just to be sure that it is working at all, touch the Enable Probe from pin 13 to Voltage.  That should FREEZE the count. Whatever the active output is, it will reamian high, and the clock signal at pin 14 will be ignored.  There will be no advance in the count.

1.  When Enable (pin 13) is connected to Voltage (High) this freezes the count. 

2.  The count should freeze on that output.

3. If the rolldown has stopped, connecting the Enable to Hi will appear to have no effect. 

4. If you keep the Enable High when you start the rolldown, it will appear that nothing happens. The current output remains high.  Nothing moves.  The scanning camera system is easy to understand, and very inexpensive.  It sells for as little as $200.  Amazing! 

5.  Pin 1 is related to output 5. 

6. That will produce a cycle through outputs 0, 1, 2, 3, 4, 0, 1, 2, ....

7. The carry out will remain Hi constantly in this set up. 

8a. The clock input (pin 14) is conditioned by the state of the output of the 4046 chip, high or low.
8b. Reset must be set low, or there will be no count.  If it is high, the count returns to Output 0.
8c. Enable must be kept low as well.  When it is set high, the count freezes at that Output.

10.  The 4017 controls which channel of the 4066 becomes active.
      The 4066 switches between channels that feed to the recording or observation unit. 

 

  Home | About EC for the EGLinks